Lab Kimia

Perkin Elmer Series 200 HPLC System



Model : Series 200
1 unit Pump, 
UV/VIS detector, 
Autosampler, 
Totalchrom software, 
Interface, 
Computer Pentium , 
Printer HP DeskJet


Series 200 Pumps :

-          Flow rate range : 0.01 to 10.0 mL/min
-          Flow rate increments :
      0.01 from 0 to 0.99 mL/min, 0.1From 1.0 to
      0.02  10 mL/min
-          Flow Precision : 0.3% RSD (typical 0.1%) at1mL/min water @ 1000 psi
-          Flow accuracy : +/- 1% of setting at 1 mL/min And 1000 psi with water

Retention time:
-          Reproducibility : < 0.3% RSD (typical < 0.1%)
-          Pressure range : 0 – 6200 psi for the entire flow-rate range
-          Composional range : 0 – 100%, solvent A to D, settable to 0.1%
-          Composional accuracy : Typical 0.5% from 3 to 97% up to 5mL/min
-          Composional precision : Typical <0.2% variation
-          Linearity : Withim 1% from 10 to 90%
-          Step time : 0 to 999 minutes
-          Step time increments : 0.1 min from 0 to 9.9 min; 1.0 min from 10 to 999 min
-          Events/method : Max of 9
-          Event increments : 0.1 min from 0 to 9.9 min; 1.0 min from 10 to 999 min

SERIES 200 UV/VIS  DETECTOR

   Programmable Functions Time, wavelength, range, rise time, auto zero, relay closures, program number, number of injections, shutdown procedure (program execution via run table) Scan Stopped flow scan, scan speed selectable from 0.2 to 1.0 nm/sec, Flowcell Backpressure: 500 psi, Self Diagnostics Self-check routine upon demand. Complete self-check routine performed upon power-up. Continuous monitoring of power supply condition, lamp status, fan operation, and leak sensor,

SERIES 200, AUTOSAMPLER 

 Injection range: Programmable from 0.1 – 1.0 uL at 0.1 uL increments, 1 uL to 2.5 mL  at 0,1 uL increments.

Replicate Injection: 1 – 99 from one vial
Precision: typically <0.5% RSD of peak areas from 3uL.
Minimum sample volume 1uL in 7 uL
Sample syringe sizes: 50, 100, 20, 500, 1000, 2500 uL.
Sample capacity: up to 225 vials or two 384 well plates.
Method parameters: Injection volume, sample draw speed, flush volume, flush cycle,  2 external contacts, start and stop time.
Display: 7-line by 40-character backlit liquid crystal display.
Include : vials for autosampler

DATA HANDLING AND CONTROLLING

Totalchrom Software, Interface, computer, Flat 15” monitor, printer HP Desk Jet



Spectrofotometer



Range ( nm ) : 190 - 1100
Double beam operation
Bandwidth ( nm ) :1 ( fixed )
Scanning, Wavelength Program, Timedrive, Rate, Quant, Scanning Quant
Application :
Routine UV/VIS testing
Liquids analysis
Pharmacopeia and regulatory test



Perkin Elmer 3100 Atomic Absorbtion Spectrophotometer






ICP Optima 3000





Gas Chromatography 


GAS CHROMATOGRAPH (GC)
Model : Autosystem-Perkin Elmer - USA, 2nd Instrument
1 unit Gas chromatograph, FID detector,
Data System complete with Total Chrom software, Interface, LINK 150,000,000

Specifications:
1x
Four level, three-ramp temperatureprogramming to 450°C (oven maximum software controlled).
Five method setup, generation, storage and copy
Up to two simultaneous analog outputs for integrator or recorder, switchable to either detector.
Digital electronic pressure readouts with capillary injectors.
Up to six solenoid valves for split vent and gas sampling valve control.
Up to 32-programmable timed events.
External computer communications allows full instrument control plus two simultaneous channels raw data
Battery RAM storage of GC methods, instrument configuration, and automationprograms.

Oven:
Volume: 10,600 cm3
Temperature range: 10°C above ambient to
450°C or –99C to 450C with subambient